Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48VRM2U, sold separately).
Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
NEMA 5-15R Outlets Protect Your Connected Components
Eight managed 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART1500RMXL2U maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.
OUTPUT
- Output Volt Amp Capacity (VA):
1500
- Output kVA Capacity (kVA):
1.5
- Output Watt Capacity (Watts):
1350
- Output kW Capacity (kW):
1.35
- Output Capacity Details:
Output is reduced to 1200 watts maximum when used with external battery packs
- Power Factor:
0.9
- Nominal Output Voltage(s) Supported:
110V, 115V, 120V
- Nominal Voltage Details:
120v nominal output in battery mode
- Frequency Compatibility:
60 Hz
- Output Voltage Regulation (Line Mode):
-14%, +6%
- Output Voltage Regulation (Battery Mode):
+/- 5%
- Output Receptacles:
(8) 5-15R
- Load Management Receptacles:
Two switchable two-outlet 5-15R load banks
- Output AC Waveform (AC Mode):
Sine wave
- Output AC Waveform (Battery Mode):
Pure Sine wave
INPUT
-Rated input current (Maximum Load):
12A
- Nominal Input Voltage(s) Supported:
120V AC
- UPS Input Connection Type:
5-15P
- Input Circuit Breakers:
15A
- UPS Input Cord Length (ft.):
10
- UPS Input Cord Length (m):
3.1
- Recommended Electrical Service:
15A 120V
- Input Phase:
Single-Phase
BATTERY
- Full Load Runtime (min.):
4.9 min. (1350w)
- Half Load Runtime (min.):
14 min. (675w)
- Expandable Battery Runtime:
Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility:
BP36V15-2U (limit 1), BP36V42-3U (multi-pack compatible), BP36V27-2US (multi-pack compatible)
- DC System Voltage (VDC):
36
- Battery Recharge Rate (Included Batteries):
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge:
RBC93-2U
- Battery Access:
Front panel battery access door
- Battery Replacement Description:
Hot-swappable, user replaceable batteries
- Expandable Runtime:
Yes
VOLTAGE REGULATION
- Voltage Regulation Description:
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
- Overvoltage Correction:
Input voltages between 127 and 145 are reduced by 12%
- Undervoltage Correction:
Input voltages between 95 and 108 are boosted by 12%
- Severe Undervoltage Correction:
Input voltages between 83 and 94 are boosted by 24%
USER INTERFACE, ALERTS CONTROLS
- Front Panel LCD Display:
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- Switches:
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
- Alarm Cancel Operation:
Power-fail alarm can be temporarily silenced using alarm-cancel switch silent mode alarm configuration option available
- Audible Alarm:
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
- UPS AC Suppression Joule Rating:
570
- UPS AC Suppression Response Time:
Instantaneous
- EMI / RFI AC Noise Suppression:
Yes
PHYSICAL
- Included Mounting Accessory Description:
4 post rackmount installation accessories included
- Installation Form Factors Supported with Optional Accessories:
2 post rackmount (2POSTRMKITWM) Wallmount (2POSTRMKITWM) Tower (2-9USTAND)
- Primary Form Factor:
Rackmount
- Rack Height (U Spaces):
2
- Cooling Method:
Fan
- UPS Housing Material:
Steel
ENVIRONMENTAL
- Operating Temperature Range:
+32 to +104OF / 0OC to +40OC
- Storage Temperature Range:
+5 to +122OF / -15OC to +50OC
- Relative Humidity:
0 to 95% non-condensing
- AC Mode BTU / Hr. (Full Load):
237
- Battery Mode BTU / Hr. (Full Load):
751
- AC Mode Efficiency Rating (100% Load):
95%
COMMUNICATIONS
- Communications Interface:
USB, DB9 Serial, EPO (emergency power off) Slot for SNMP/Web interface
- Network Management Cards:
SNMPWEBCARD, TLNETCARD, WEBCARDLX
- Network Monitoring Port Description:
Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software:
For local monitoring via the UPSs built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable:
USB and DB9 cabling included
- WatchDog Compatibility:
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
- Transfer Time:
4 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode)
- Low Voltage Transfer to Battery Power (Setpoint):
83
- High Voltage Transfer to Battery Power (Setpoint):
145
SPECIAL FEATURES
- Grounding Lug:
Back panel grounding lug
- Cold Start (Startup in Battery Mode During a Power Failure):
Cold-start operation supported
- High Availability UPS Features:
Hot swappable batteries
- Green Energy-Saving Features:
Greater than 95% efficiency - GREEN UPS,
Individually controllable load banks
CERTIFICATIONS
-UPS Certifications:
Meets FCC Part 15 Category A (EMI), ROHS (Restriction of Hazardous Substances), Tested to CSA (Canada) Tested to NOM (Mexico), Tested to UL1778 (USA)
Package Includes
-SMART1500RMXL2UA SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS
-USB cable
-DB9 cable
-EPO cable
-Mounting hardware
-Owners manual
Item Dimension (L inchxW inchxH inch)
9 x 23 x 20
Weight
57.80lb
Warranty Information
2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.