0
Categories
Eaton PDUMVR30HVNETLX PDU - Tripp Lite by 5.5kW Single Phase Switched Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA NEMA L6 30P 20 x IEC 60320 C13, 4 x IEC 60320 C19 230 V 5.80 kVA 0U Vertical Rackmount TAA Compliant
Eaton PDUMVR30HVNETLX PDU - Tripp Lite by 5.5kW Single Phase Switched Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA NEMA L6 30P 20 x IEC 60320 C13, 4 x IEC 60320 C19 230 V 5.80 kVA 0U Vertical Rackmount TAA Compliant Eaton PDUMVR30HVNETLX PDU - Tripp Lite by 5.5kW Single Phase Switched Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA NEMA L6 30P 20 x IEC 60320 C13, 4 x IEC 60320 C19 230 V 5.80 kVA 0U Vertical Rackmount TAA Compliant Eaton PDUMVR30HVNETLX PDU - Tripp Lite by 5.5kW Single Phase Switched Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA NEMA L6 30P 20 x IEC 60320 C13, 4 x IEC 60320 C19 230 V 5.80 kVA 0U Vertical Rackmount TAA Compliant

Eaton PDUMVR30HVNETLX PDU - Tripp Lite by 5.5kW Single Phase Switched Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA NEMA L6 30P 20 x IEC 60320 C13, 4 x IEC 60320 C19 230 V 5.80 kVA 0U Vertical Rackmount TAA Compliant

The PDUMVR30HVNETLX 5/5.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19). LEDs indicate each outlet's on/off power status, and you can monitor each outlet's power consumption remotely or via digital display. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform interface enables full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital LED meter allows you to monitor each bank's load in real time to ensure the PDUMVR30HVNETLX is used at maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the includedPDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

More from the Manufacturer

Manufacturer: TRIPP LITE SUPPORT
MPN: PDUMVR30HVNETLX
Availability: In stock
Condition: New
CA Proposition 65: None
$1,549.88
Add to Wishlist

Product Description

Technical Information
  • Plug/Connector Type:
    NEMA L6-30P
  • Receptacle Type:
    IEC 60320 C13, IEC 60320 C19
  • Receptacle Detail:
    20 x IEC 60320 C13, 4 x IEC 60320 C19
  • Protection Type:
    Overload Protection
Power Description
  • Input Voltage:
    230 V AC
  • Output Voltage:
    230 V AC
  • Power Rating (Watt):
    5800 W
  • Input Current:
    30 A
Management
  • Management:
      • HTTP
      • HTTPS
      • PowerAlert
      • SMTP
      • SNMPv1
      • SNMPv2
      • SNMPv3
      • Telnet
      • SSH
      • FTP
      • DHCP and NTP

Physical Characteristics
  • Mounting Orientation:
    Vertical
  • Mount Type:
    Rack-mountable
  • Rack Height:
    0U
  • Height:
    70"
  • Width:
    2.2"
  • Depth:
    2.6"
  • Weight (Approximate):
    12 lb
Miscellaneous
  • Country of Origin:
    Taiwan
  • TAA Compliant:
    Yes
  • Environmentally Friendly:
    Yes
  • Environmental Compliance:
    Restriction of Hazardous Substances (RoHS)

OVERVIEW
PDU Type: Switched
OUTPUT
Output Capacity Details: 5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank 16A max per C19 outlet 12A max per C13 outlet
Frequency Compatibility: 50 / 60 Hz
Output Receptacles: (20) C13 (4) C19
Output Nominal Voltage: 200 208 240
Overload Protection: Two 20A breakers protect 12 outlets each
Customized Load Management Receptacles: Each outlet is individually controllable via remote interface
INPUT
PDU Input Voltage: 200 208 240
Recommended Electrical Service: 30A 208/240V
Maximum Input Amps: 30
Maximum Input Amps Details: Agency de-rated to 24A continuous
PDU Plug Type: NEMA L6-30P
Input Cord Length (ft.): 10
Input Phase: Single-Phase
USER INTERFACE, ALERTS AND CONTROLS
Front Panel LCD Display: Digital display reports load level in amps for LOAD BANK 1 (Outlets 1-12), LOAD BANK 2 (Outlets 13-24), LOAD BANKS 12 COMBINED (Outlets 1-24) and each individual output receptacle Digital display can also be used to scroll the configured IP address
Front Panel LEDs: BANK 1 and BANK 2 LEDs verify which load bank the digital current display is reporting (Bank 1, Bank 2 or Banks 12 Combined) BANK 1 or BANK 2 LED will flash when the digital display is reporting output current for one of the outlets in that load bank 24 additional LEDs, one near each output receptacle, will light continuously to verify power on/off status and flash to indicate that the digital display is reporting output current for just that individual receptacle
Switches: SELECT OUTLET and SELECT BANK switches advance the LCD screen and associated LED to display power consumption for individual output receptacles and output load banks Press and hold the SELECT BANK button for 4 seconds to rotate the digital display 90 degrees for overhead power input Press and hold the SELECT OUTLET button for 4 seconds to scroll the configured IP address
PHYSICAL
Form Factors Supported: 0U vertical rackmount includes rackmount brackets. Supports toolless mounting in button-mount compatible racks
PDU Form Factor: 0U Vertical
ENVIRONMENTAL
Storage Temperature Range: 5 to 122F (-15 to 50C)
Relative Humidity: 5 to 95% non-condensing
Operating Elevation (ft.): 0-10,000
Operating Elevation (m): 0-3000
COMMUNICATIONS
SNMP Compatibility: Built-in LX-Platform network interface provides remote monitoring via web, Telnet, and SNMP. Remote management enables outlets to be turned on and off individually
CERTIFICATIONS
Certifications: Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
Item Dimension (L"xW"xH")
5 x 7 x 76

Weight
17 lbs

Warranty Information
2-year limited warranty