Eaton PDU3EVSR10L2130 PDU - Tripp Lite by 10kW 200 240V 3PH Switched LX Interface Gigabit 30 Outlets L21 30P Input LCD 3 m Cord 0U 1.8 m Height TAA Switched NEMA L21 30P 24 x IEC 60320 C13, 6 x IEC 60320 C19 230 V AC Network (RJ 45) 0U Vertical
Eaton PDU3EVSR10L2130 PDU - Tripp Lite by 10kW 200 240V 3PH Switched LX Interface Gigabit 30 Outlets L21 30P Input LCD 3 m Cord 0U 1.8 m Height TAA Switched NEMA L21 30P 24 x IEC 60320 C13, 6 x IEC 60320 C19 230 V AC Network (RJ 45) 0U Vertical Eaton PDU3EVSR10L2130 PDU - Tripp Lite by 10kW 200 240V 3PH Switched LX Interface Gigabit 30 Outlets L21 30P Input LCD 3 m Cord 0U 1.8 m Height TAA Switched NEMA L21 30P 24 x IEC 60320 C13, 6 x IEC 60320 C19 230 V AC Network (RJ 45) 0U Vertical

Eaton PDU3EVSR10L2130 PDU - Tripp Lite by 10kW 200 240V 3PH Switched LX Interface Gigabit 30 Outlets L21 30P Input LCD 3 m Cord 0U 1.8 m Height TAA Switched NEMA L21 30P 24 x IEC 60320 C13, 6 x IEC 60320 C19 230 V AC Network (RJ 45) 0U Vertical

The PDU3EVSR10L2130 10kW 3-Phase Switched Power Distribution Unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 0U PDU features 30 switched outlets (24 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L21-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A color touchscreen LCD lets you toggle between menus to monitor input current level per phase, output current per load bank and per outlet with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the switchable PDU through a mobile device.

Features

Distributes, Monitors and Manages Network-Grade AC Power

  • 10kW 200/208/240V switched PDU with 3-phase input
  • Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components
  • NEMA L21-30P plug with 10 ft. cord connects to compatible AC power source
  • Firmware upgrades support future product enhancements

30 Switched Outlets Distribute AC Power

  • 24 C13 and 6 C19 outlets split into 3 separately breakered load banks
  • Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices
  • Plug-lock insert sleeves prevent cables from becoming accidentally disconnected

Color Touchscreen LCD

  • Reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy
  • Generates unique QR code for read-only access to PowerAlert® Device Manager via mobile device
  • Full access available by logging into PowerAlert Device Manager via browser as user with read/write credentials

Built-In LX Platform Interface

  • Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
  • Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
  • No Java required

Broad Communications Compatibility

  • Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP
  • Supports automatic and manual assignment of IP address

Easy 0U Installation in EIA-Standard 19 in. Racks

  • Mounts vertically using included toolless buttons or rack-mounting brackets
  • Included PDUMVROTATEBRKT allows mounting with rear-facing outlets
Manufacturer: TRIPP LITE SUPPORT
MPN: PDU3EVSR10L2130
Availability: Special Order
Condition: New
$2,034.33
Add to Wishlist

Product Description

Technical Information
  • PDU Type:
    Switched
  • Design:
    Modular
  • Phase:
    Three Phase
  • Plug/Connector Type:
    NEMA L21-30P
  • Receptacle Type:
    IEC 60320 C13, IEC 60320 C19
  • Receptacle Detail:
    24 x IEC 60320 C13, 6 x IEC 60320 C19
  • Protection Type:
    Overload Protection
Power Description
  • Input Voltage:
    230 V AC
  • Output Voltage:
    230 V AC
  • Power Rating (Watt):
    10 kW
  • Input Current:
    24 A
Management
  • Management:
      • IPv4
      • IPv6
      • HTTP
      • HTTPS
      • SMTP
      • SNMPv1
      • SNMPv2
      • SNMPv3
      • telnet
      • SSH
      • FTP
      • DHCP
      • NTP

Interfaces/Ports
  • Network (RJ-45):
    Yes
Physical Characteristics
  • Mounting Orientation:
    Vertical
  • Mount Type:
    Rack-mountable
  • Rack Height:
    0U
  • Height:
    70"
  • Width:
    2.2"
  • Depth:
    2.9"
  • Weight (Approximate):
    20.01 lb
Miscellaneous
  • Country of Origin:
    Taiwan
  • TAA Compliant:
    Yes
  • Environmentally Friendly:
    Yes
  • Environmental Compliance:
    Restriction of Hazardous Substances (RoHS)

OUTPUT
Frequency Compatibility
50 / 60 Hz
Output Capacity Details
10kW (240V), 8.6kW (208V) total capacity, 13.9A max per breakered outlet bank, 12A max per C13 outlet
Output Receptacles
(24) C13, (6) C19
Output Nominal Voltage
208, 240
Overload Protection
3 20A circuit breakers, one per output load bank
Customized Load Management Receptacles
Each outlet is individually controllable
INPUT
PDU Input Voltage
208, 240
Recommended Electrical Service
30A 208/240V with L21-30R outlet
Maximum Input Amps
24
PDU Plug Type
NEMA L21-30P
Input Phase
3-Phase
Input Cord Length (ft.)
10
Input Cord Length (m)
3.05
USER INTERFACE, ALERTS and CONTROLS
Reported Load Segments
Reports input current per phase (L1, L2, L3), plus output current for each output load bank (20A balanced max per banks B1-B3) and individual output receptacle (1-30), Outlets are color-coded and labeled for phase and load bank identification, L1-L2 feeds light-gray outlets (B1), L2-L3 feeds black outlets (B2), L3-L1 feeds dark-gray outlets (B3)
Front Panel LCD Display
Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), OUTLET DATA (Amperage, Wattage per outlet), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules, Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Front Panel LEDs
One LED for each output receptacle offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip), LED OFF (Power OFF). Network Activity (Green): Flashes for network activity. Link/Network Speed (Yellow): On steady for any speed.
Switches
LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Current Measurement Accuracy (Amps)
+/-1%
Voltage Measurement Accuracy (Volts)
+/-1%
Power Measurement Accuracy (Watts)
+/-1%
PHYSICAL
Form Factors Supported
Vertical rackmount installation supported with included mounting brackets, supports toolless mounting in buttonmount compatible racks
Material of Construction
Metal
PDU Form Factor
Vertical (0U)
ENVIRONMENTAL
Operating Temperature Range
32 to 122F (0 to 50C)
Storage Temperature Range
-30oC to +60oC (-22oF to +140oF)
Relative Humidity
5 to 95% non-condensing
COMMUNICATIONS
PowerAlert Software
LX Platform Interface: PowerAlert Device Manager15 (PADM15)
Communications Cable
USB B-to-USB A Configuration/Console Access cable
Network Monitoring Port
RJ45 Network port, RJ45 Config/Console Access port, 2x USB A ports supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. USB B port (Configuration and Console Access)
SNMP Compatibility
SNMP V1, V2c, V3
Network Speed
10/100 Mbps, 1Gbps
Communications Interface
Pre-installed network card, RS-232, USB
CERTIFICATIONS
Certifications
Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada), Class A Part 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
Item Dimension (L"x W"x H")
7 x 10 x 76
Weight
39.00 LB
Warranty Information
2-year limited warranty